I get this question several times a week, and I want to give everyone who asks a clear and accurate response without ignoring them (which I sometimes do). This blog post is how I can do that efficiently, and be more organized and mindful about the progress.
tl;dr:
- The renovation part of the renovation project hasn’t started.
- The preparation part of the renovation project has been going on since August 2020.
- I do not know when we’ll be done, or when we’ll have a permit, or when construction will start.
“Why is it taking so long?” is the question that people don’t ask aloud, but I guess that my friends are like me and curious.
It’s taking a long time because my architect and I don’t spend a whole lot of time working on the project. It’s all relative, of course. We spend about 10 hours a week on this (at most), and that includes a lot of learning and research.
We both have full-time jobs, have other things to work on, and our experience in this arena is limited. My architect, who prefers to stay out of the blogging spotlight, is extremely experienced in multi-family new construction residential architecture, though. We also rely heavily on the input of friends and neighbors who live in similar houses and have experience dealing with the construction idiosyncrasies of old buildings in Chicago. I also rely on the input of other architects who are experts in designing renovated and new construction one, two, and three-unit houses (thank you K.D. and P.M.).
This is a learning process for both of us. There are so many decisions to make, independently and together. We both want to be deeply involved in understanding what it takes to buy and gut rehab a house that I will live in. If we do it well this time, it would make it easier for either one of us to do it again for a different house.
What we’ve done in the past two weeks
- I invited a fourth general contractor into the house to take a look. I am not getting estimates yet from these four GCs because the plans / permit drawings aren’t far enough along. Each GC, however, has reviewed the current plans prior to the visit so it’s easier to point and explain what’s going to change.
- One of the big things that will change is replacing the wooden center beam in the basement to a steel I-beam, and changing out some of the joists. This will require temporarily shoring (supporting) the joists. Each GC has had a slightly different opinion on the procedure. But we get to hear each procedure and come up with the one we think is best.
- I received and organized three quotes for all-new windows, as well as researched and modified the window schedule. “Organizing” the quotes means adding a new column to my window schedule spreadsheet with each manufacturer’s pricing so I can compare them. Part of window research is figuring out the type of window I want for each room and opening and assessing the quality of the manufacturer. For example:
- I am learning that casement windows are more energy efficient because they create a better seal when closed and locked than hung windows.
- I prefer single-hung windows to double-hung windows, but some manufacturers don’t make single-hung windows.
- Every manufacturer has different maximum window heights. One of the openings is 80 inches tall and, for one manufacturer, the maximum height for a casement window is 72 inches and the maximum height for their hung windows is 75 inches. Thus, the estimator added transom windows to all openings that exceeded their maximums. That’s fine, but then it adds a new decision point: What proportion should be operable windows and what proportion should be transom windows?
- My architect continued talking to the structural engineer I hired to make sure the engineer’s drawing has the right details and lists the specifications we asked him to write out on the drawing.
- Settled on an HVAC system. For a couple months I’ve been researching mini-splits off and on. I got an estimate for equipment + installation from one company, which was much higher than I expected. I combined their projections for required heating capacity with projections from others, as well as CoolCalc.com, to settle on a lower capacity.
- I started looking at more retailers who will sell mini-split systems directly to the consumer, or the GC, to get grounded in pricing and availability. Then, when I was done specifying the schedule, my architect took a look at the designs and the cut sheets, and figured out where the indoor units should go. He recommended choosing the cassette style that gets mounted within the ceiling between two joists. It costs more, but it looks a lot better since there’s not a big box hanging on the wall in the living room and kitchen.
- Last Friday my architect and I visited a “near Passive House” standard three-flat being built in Pilsen. The developer, who will live in one of the units, also used mini-splits, from Mitsubishi. It was cool to see them installed (on the roof) and how they were connected to an air handler that serves as the blower to push the air through a traditional duct and out via an “energy recovery ventilator” (in the winter, the warmth of the outgoing air is transferred to the fresh incoming air so the machinery has to expend less energy warming up cold air).
While I was writing this, another of the four GCs that toured the house checked in. I told them that after this week we’ll have made significant progress since my architect has the week off of work.
What we’re working on next
- Last week, my architect started drawing a window detail in the plans because there are good ways of installing windows and bad ways. I don’t fully understand them, so I’m not going to write about them here, but he did explain them to me and pointed out some good examples in his house and some bad examples in someone else’s house.
- Finish the “panelboard schedule”. This diagram shows each circuit that will be in a breaker box, and labels them according to the circuits in the electrical drawings. Not every circuit breaker will be identical, as some circuits – like the ones for the water heater and mini-splits – need 30 or 40 amp breakers.
- I am going to research the construction type’s fire protection requirements by reading the Chicago Building Code and noting the required fire ratings for the basement ceiling, the ceiling between floors, the interior front door’s rating, the roof rating, the rating for the light well wall, and the rating requirement for load bearing walls.
What I’m worried about
All of the decisions that have to be made. See the three points about windows above. I’ve got three quotes for the windows, all based on about the same schedule. But after I receive the fourth quote that I’m expecting this week, my desire for certain windows may change. I may want more casement windows, or different proportions of transom windows and casement-picture-casement window layouts.
The cost of everything. I have significant savings but I will still need to borrow some money. I need to start researching the universe of options and the availability of options. On top of this, lumber pricing has doubled since the start of the COVID-19 pandemic.